Checking Fan Belt - Shindaiwa DG1000MI Owner's And Operator's Manual

Sound proof diesel engine generator
Hide thumbs Also See for DG1000MI:
Table of Contents

Advertisement

Replace LLC every 2 years or 1000 hours
Mixture ratio (for reference only) :
Ambienr
temperature
(Celsius)
Mixture ratio
8.2.3 Coolant Capacity

8.3 Checking Fan Belt

A lso refer to the user's manual for Engine separately
※ ※ ※ ※
Danger
Before performing any equipment check or maintenance, stop the engine,
and remove the engine key. A person performing the maintenance should always
keep the key.
Close all doors and place locks during operating this equipment, to avoid injuries
by unintentionally touching cooling fan and fan belt.
Caution
Do not touch the engine and muffler during operation and immediately after stopping
the equipment, for the temperature can reach extremely high
8.3.1 Tension
Tension should be optimum when the fan belt has 10 to
15mm slacks, when applying finger pressure (about
98N{approximately 10kgf}) at midpoint between fan
pulley and alternator pulley.
-15
℃ ℃ ℃ ℃
30%
Total Coolant Volume ( including reservoir tank)
The value of ( ) shows the reservoir tank`s volume.
:Injuries
:Burns
-20
℃ ℃ ℃ ℃
-30
℃ ℃ ℃ ℃
35%
45%
22.8 (1.5)
- 28 -
( Unit: L)