Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
How To... REPLACE THE DIGITAL HEART RATE PC BOARD (LC9500HR)
Tools Required: Phillips screwdriver, pliers
1. Remove the four SCREWS securing the DISPLAY CONSOLE to the DISPLAY CONSOLE BRACKET.
2. Unplug the 10-PIN CONNECTOR, 4-PIN CONNECTOR, and the 3-PIN CONNECTOR from the back of the
DISPLAY CONSOLE.
3. Remove the SCREWS securing the back of the DISPLAY CONSOLE to the OVERLAY FACE-PLATE. Set the
OVERLAY face down on a non-abrasive, flat surface.
4. Ground yourself to the machine by attaching one end of a DISPOSABLE ANTI-STATIC GROUNDING STRAP
to your wrist and the other to a suitable grounding point on the exercise bike (e.g.: the metal part of the pedal
crankshaft).
5. Use the pliers to squeeze the tips of the five SPACERS, one at a time, to allow removal of the HEART RATE
PC BOARD. Before lifting the HEART RATE PC BOARD from position, be aware that an 8-PIN
CONNECTOR is also securing the back of the board in place.
6. Replace any damaged SPACERS with those included in the kit.
7. Reverse Steps 1 through 5 to replace all parts in their proper positions.
Display Console model
shown for reference only.