Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
How To...REPLACE THE MAIN WIRE HARNESS
Tools Required: 1/4, 5/16, and 3/8 inch wrenches, side cutters, and standard screwdriver
1. Refer to "How To...Replace Display
Console and Handle Bar" in this section to
remove the HANDLEBAR ASSEMBLY
and disconnect the MAIN WIRE
HARNESS connectors.
2. Refer to "How To...Replace Shrouds" in
this section to remove the right SHROUD.
3. For the LC9500HR only, disconnect the
BLACK (neg) wire from the (-) post on the
BATTERY, then the RED (pos) wire from
the (+) post.
4. Disconnect the MAIN WIRE HARNESS
(P1) at the ALTERNATOR CONTROL
BOARD.
5. Note the location of the CABLE TIES on
frame, then cut them off.
6. Route the MAIN WIRE HARNESS out
through the bottom FRAME TUBE and
secure with new cable ties.
7. Install the new MAIN WIRE HARNESS in the reverse order of the above steps.
Main Wire Harness
(in handle bar)
Main Wire Harness
Frame Tube
(in frame tube)
Tie
Strap
13