DIAGNOSTICS STATE 4 - LIFEPULSE TESTS (Integrated PCB Only)

Upon entry to this diagnostic state, the LIFEPULSE software version number is displayed for 2 seconds. After this ,
the LP Comm Status is displayed for 2 seconds, which will either display 'LP PC COMM ON' or 'LP PC COMM
OFF'. Make sure 'LP PC COMM OFF' appears, or CSAFE will not function correctly. The LP Comm Status can be
toggled by pressing the 5 key during the 2 seconds when the LP Comm Status message is being displayed, and
does not normally need to be adjusted.
After these messages are done displaying, the LifePulse test information comes up.
With both hands placed on the LifePulse sensors, the ELAPSED TIME begins counting in the TIME window. This
counter will stop counting as soon as a heart rate is displayed.
The GAIN is displayed in the RPM window.
The CONFIDENCE LEVEL between 0-9 is displayed in the CALORIES/HOUR window, with 0 indicating the lowest
confidence and 9 indicating the highest.
The profile window will display and 'L' when the left LifePulse sensor is being held. An 'R' when the right LifePulse
sensor is being held, and 'L' and 'R' when both sensors are being held.
Press the 'CLEAR/PAUSE' key to return to DIAGNOSTICS STATE 3.
Press the 'START/ENTER' key to advance to DIAGNOSTICS STATE 5.