Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
How To...REPLACE THE ALTERNATOR BELT
Tools Required: Combination wrenches, pliers, screwdrivers, e-ring tool, center punch, and belt tensioning gage
1. See "How To...Replace Shrouds" in this
section.
2. Mark the position of the ALTERNATOR
TENSIONING BOLT at the MOUNTING
BRACKET, then remove TENSIONING
BOLT.
3. Loosen the ALTERNATOR PIVOT BOLT
and push the ALTERNATOR forward to
slacken the ALTERNATOR BELT.
4. Mark the position of the IDLER BRACKET,
Remove and loosen MOUNTING BOLTS
as illustrated.
5. Loosen the TENSION BOLT and move the
IDLER BRACKET forward to slacken the
POWER GRIP BELT.
Idler Bracket
Tensioning Bolt
Torque 5-7 FT. LBS.
Mounting Bolt (Loosen)
Torque 27-33 IN. LBS.
Mounting Bolt (Remove)
Torque 27-33 IN. LBS.
Alternator
Mounting
Bracket
Alternator
Tensioning Bolt
Torque 18-20 FT. LBS.
Alternator Pivot Bolt
Torque 30-35 FT. LBS.
Alternator Belt
Power Grip Belt
3