Processors
6.3

Replacing the heat sink

Ê Open the server and remove system fan 2 (or 2&4) as described in the
chapter "Preparation" on page
Ê Press the heat sink retaining clips downward and inward to release them.
Ê Swing the heat sink retaining clips up as far as they will go.
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink.
Ê Mount the heat sink on the processor so that the side with the visible copper
heat pipes is pointing in the direction of the memory slots.
Ê Fold down the two heat sink retaining clips at the same time and lock the
heat sink by returning the heat sink retaining clips to their original position.
Ê Reinstall system fan 2 (or 2&4) as described in the
fan 2 (or 2&4)" on page
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter "Completion" on page
50