Ê Push the right-hand side cover in the direction of the arrow.
Ê Lift off the right-hand side cover.
I
The right-hand side cover is no longer required.
Ê Lay the server on its right-hand side.
V
CAUTION!
Get a second person to help you do this. The server can weigh up to
35 kg.
Figure 86: Removing the foot mounting rail
Ê Loosen the three screws (1) of the foot mounting rail.
Ê Slide the foot mounting rail backward (2) until the hooks disengage.
Ê Take off the foot mounting rail.
I
The foot mounting rail is no longer required.
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the front panel module can be taken out simply, turned
through 90° to the left, and then be reinstalled.
Ê Remove the dummy covers from the drive cage
Ê Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
TX200 S6
Conversion from a floorstand model to a rack model
Options Guide
(figure 22 on page
54).
103