CPU population requirements
– Slot CPU1 must be populated first.
– All CPUs must operate at the same Intel® Quick Path Interconnect
frequency and core frequency.
For system relevant information, see the hardware configurator of your
server available online at the following address:
https://www.fujitsu.com/emeia/products/computing/servers
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/
11.3
Replacing a CPU or heat sink
Field Replaceable Unit
(FRU)
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for CPU node)
– T30 Torx screw driver
CAUTION
CPUs are extremely sensitive to electrostatic discharge and therefore
must always be handled with care.
▶
After a CPU has been removed from its protective sleeve or from its
socket, place it upside down on a nonconducting, antistatic surface.
▶
Never push a CPU over a surface.
Preliminary steps
▶
"Locating the defective server" on page
▶
"Shutting down the server" on page
▶
"Disconnecting the power cord" on page
▶
"Getting access to the component" on page
▶
"Handling the CPU node" on page
GX2570 M6
40.
49.
Upgrade and Maintenance Manual
Hardware: 20 minutes
39.
40.
41.
Processor (CPU)
167