Brother DCP-7030 Service Manual page 279

Laser multi-function center
Hide thumbs Also See for DCP-7030:
Table of Contents

Advertisement

<WSW35>
Selector No.
1
Max. detection period of dial
I
tone/busy tone during recording
of ICM (Not used.)
4
5
I
Not used.
8
Note:
Selectors 1 through 4 are applicable to models equipped with internal TADs.
• Selectors 1 through 4: Max. detection period of dial tone/busy tone during recording
If the machine (called station) detects dial tone or busy tone exceeding the detection level
specified by selectors 1 through 3 on WSW30 for the period specified by these selectors,
then it disconnects the line.
<WSW36>
Selector No.
1
ECP mode* (Not used.)
Recovery from Inactive PC
2
Interface (Not used.)
PC Power-off Recognition Time
3
(Not used.)
4
Not used.
5
Escape from phase C
6
Extension of incoming calling
signal (CI) frequency band
I
specified by selectors 1 through
8
4 on WSW14
Note:
Selectors 2 and 3 will become operative if selectors 1 and 2 of WSW46 are set to "monitor"
the PC power ON/OFF state.
Function
of ICM (Not used.)
Function
App. 1-40
Setting and Specifications
No. 1 2 3 4
0 0 0 0: No detection
0 0 0 1: 1 sec.
0 0 1 0: 2 sec.
0 1 0 0: 4 sec.
|
1 1 1 1: 15 sec.
Setting and Specifications
0: ON
1: OFF
0: Disable
1: Enable
0: Normal
1: Long
0: Yes
1: No
No. 6 7 8
0 0 0: 0
(Ignored)
0 0 1: 4
(448 Hz)
0 1 0: 8
(244 Hz)
0 1 1: 12
(162 Hz)
1 0 0: 16
(122 Hz)
1 0 1: 20
(97 Hz)
1 1 0: 24
(81 Hz)
1 1 1: 28
(69 Hz)
*ECP (Enhanced Capabilities Port)
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents