<WSW14>
Selector No.
Frequency band selection (lower
1
limit) for incoming calling signal
2
(CI)
Frequency band selection
3
(upper limit) for incoming calling
4
signal (CI)
5
I
No. of rings in AUTO ANS mode
8
• Selectors 1 through 4: Frequency band selection for incoming calling signal (CI)
These selectors are used to select the frequency band of CI for activating the AUTO ANS
facility.
In the French models, if the user sets the PBX to OFF from the control panel, the setting
made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to
32 Hz. (Even if the setting made by these selectors does not apply, it will be printed on the
configuration list.)
• Selectors 5 through 8: No. of rings in AUTO ANS mode
These selectors set the number of rings to initiate the AUTO ANS facility.
Function
No. 1 2
No. 3 4
No. 5 6 7 8
App. 1-19
Setting and Specifications
0 0: 13 Hz
0 1: 15 Hz
1 0: 23 Hz
1 1: 20 Hz
0 0: 30 Hz
0 1: 55 Hz
1 0: 70 Hz
1 1: 200 Hz
0 0 0 0: Fixed to once
0 0 0 1: 1 to 6 times
0 0 1 0: 1 to 8 times
0 0 1 1: 2 to 8 times
0 1 0 0: 1 to 2 times
0 1 0 1: 1 to 3 times
0 1 1 0: 1 to 4 times
0 1 1 1: 1 to 5 times
1 0 0 0: 2 to 3 times
1 0 0 1: 2 to 4 times
1 0 1 0: 2 to 5 times
1 0 1 1: 2 to 6 times
1 1 0 0: 1 to 10 times
1 1 0 1: 2 to 10 times
1 1 1 0: 3 to 5 times
1 1 1 1: 4 to 10 times