• Selectors 8: Limitation on CNG detection
If this selector is set to "1," the machine detects a CNG signal according to the condition
preset by selectors 2 and 3 on WSW18 after a line is connected. If it is set to "0," the
machine detects a CNG signal as long as the line is connected.
<WSW21>
Selector No.
1
Max. waiting time for voice
I
signal (Not used.)
5
6
Taping the call (Not used.)
7
Erasure of message stored in
8
the memory after the message
transfer
Note:
• Selectors 1 through 5 are applicable to models equipped with ICM recorders.
• Selectors 6 through 8 are applicable to models equipped with TADs.
• Selectors 1 through 5: Max. waiting time for voice signal (Not used.)
In the TAD mode, the machine waits for voice signal for the time length specified by these
selectors before it automatically shifts to the facsimile message receive mode or
disconnects the line.
• Selectors 6 and 7: Taping the call (Not used.)
These selectors select whether or not to tape the call. Setting them to "1, 0" enables taping
the call without signaling to the calling station that the call is being taped.
• Selector 8: Erasure of message stored in the memory after the message transfer
Setting this selector to "0" will erase the message recorded in the memory after the
document retrieval feature transfers the message.
Function
No. 1 2 3 4 5
No. 6 7
App. 1-26
Setting and Specifications
0 0 0 0 0: No detection
0 0 0 0 1: 1 sec.
0 0 0 1 0: 2 sec.
0 0 0 1 1: 3 sec.
|
0 0 1 1 0: 6 sec. (Default)
|
1 1 1 1 1: 31 sec.
0 0: Enable (signaling for
U.S.A.)
0 1: Enable (signaling for
countries except U.S.A.)
1 0: Enable (without signaling) (C)
1 1: Disable
0: Yes
1: No
(A)