Mobile Home Installation

These appliances can be installed for use in a mobile
home in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.
Use the Jøtul Floor Bracket Kit appropriate for your
stove's leg; see the Accessories listing on p. 29.
2. Provision must be made to secure an electrical ground
between the stove and the mobile home chassis.
3. The stove is installed in accordance with Title 24 CFR,
Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with CSA
Z240.4, Gas Equipped Recreational Vehicles and Mobile
Housing.
4. Always contact your local officials about installation
restrictions and requirements in your area.
THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLA-
TION IN A MANUFACTURED (MOBILE) HOME AND MUST
BE INSTALLED IN ACCORDANCE WITH THE MANUFAC-
TURER'S INSTRUCTIONS AND THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,
PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE
TYPE OF GAS THAT IS INDICATED ON THE STOVE'S RATING
PLATE. A GAS CONVERSION KIT IS PROVIDED WITH THE
NORDIC QT DIRECT VENT GAS STOVE.
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR-
KET PERMANENTLY LOCATED, MANUFACTURED (MOBILE)
HOME, WHERE NOT PROHIBITED BY LOCAL CODES.
CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON
PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI
LES REGLEMENTS LOCAUX LE PERMETTENT. CET APPAR-
EIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE
GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE. NE PAS
L'UTILISER AVEC D'AUTRES GAS SAUF SI UN KITDE CON-
VERSION CERTIFIE EST INSTALLE.

Fuel Conversion

Your gas stove is shipped from the factory equipped to
burn NATURAL GAS only. If PROPANE gas is to be used as
fuel, the appliance must first be converted for use with
propane.
Jøtul GF100 DV II Nordic QT: Use Propane Conversion Kit
155628, supplied with the appliance.
Jøtul GF200 DV II Lillehammer: Use Propane Conversion
Kit 155626, supplied with the appliance.
THE CONVERSION KIT IS TO BE INSTALLED BY
AN AUTHORIZED JØTUL SERVICE TECHNICIAN
IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTION AND ALL CODES AND REQUIREMENTS
OF THE AUTHORITY HAVING JURISDICTION. FAILURE
TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN
SERIOUS INJURY OR PROPERTY DAMAGE.
THE QUALIFIED AGENCY PERFORMING THIS WORK
ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE
PROVINCIAL AUTHORITIES HAVING JURISDICTION
AND IN ACCORDANCE WITH THE REQUIREMENTS OF
THE CAN1-B149.1 AND .2 INSTALLATION CODE.
Tools required:
• 1/2" open ended wrench or deep-well socket, Torx T20
or slotted screwdriver, 4 mm allen wrench.
Conversion Kit Contents:
• 1, regulator tower labeled for propane
• 3, regulator tower screws
• 1, burner orifice (GF 100: #48 for NG, #56 for LP)
(GF 200: #46 for NG, 1.20 mm for LP)
• 1, pilot orifice (#51 for NG, #30 for LP)
• Label A - to be completed and applied to
the back of the stove
• Label B - apply to the stove's Rating Plate
• Small valve label - apply to valve body
Conversion instructions are also shipped in the stove
with the conversion kit.
138003_Rev_K / 7.29.10