Orifice
Figure 20.
Pilot orifice removal and replacement.
Apply small
label
Figure 21. Regulator Assembly.
Pilot Head
Burner Plate
Figure 22.
Check burner plate / pilot head alignment. Burner is
secure, and level. The pilot head protrudes above the
burner surface.
Pilot Head
Retainer
Clip
Pilot Base
Gasket
Regulator
Tower
Mounting
Screws

Gas Supply Connection

NOTE: If the optional Blower will be installed, use a 90°
Elbow off the valve to create adequate clearance for the
main gas line.
The gas supply line connection is made to the valve just
inside the left rear leg. The gas supply line should be 3/8"
npt with a 1/2" diameter supply, or the appropriate size to
provide sufficient gas pressure to the valve regardless of
the input setting.
The use of a Flexible Gas Appliance Connector is
acceptable in many areas in the U.S. However, Canadian
methods vary depending on local code.
ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE
OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH
THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS
CODE ANSI Z223.1/NFPA 54 OR CAN-B149.
All codes require a gas shut-off valve (gas cock) and
union, to be installed in the supply line, and in the same
room as the appliance. This allows for the disconnection
of the stove for servicing and maintenance. See fig. 23.
A T-HANDLE GAS COCK IS REQUIRED IN
MASSACHUSETTS TO COMPLY WITH CODE 248CMR.
Secure all joints tightly using appropriate tools and
sealing compounds. For propane units be sure to use com-
pounds that are propane resistant. Turn on gas supply and
test for gas leaks using a soapy water solution. Never use
an open flame to check for leaks.
Leak test:
1. Use an electronic gas detector, or mix a 50-50 solution
of water and dish soap.
2. Light appliance- see lighting instructions on the inside
back cover of this manual or on the stove's rating plate.
3. Brush or spray all joints and connections with the
soapy water solution.
4. If bubbles appear at any connection or seam or a gas
odor is detected, immediately turn gas control knob to
the OFF position.
5. Tighten or reconnect the leaking joint and retest for
any gas leaks.
1/2” x 3/8” Flare
Shut-off Valve
Figure 23.
Supply
valve
coupling.
Gas Stub
1/2” x 3/8”
Reducer
138003_Rev_K / 7.29.10
3/8” NPT x 3/8”
Flare Fitting
3/8” Flex Tubing
3/8”Nipple
3/8” Union
3/8” Close Nipple
3/8” Shut-off
Valve
17