High Altitude Adjustment

Installations burning natural gas and located at altitudes
from 2000 - 4500 ft. (610 M - 1370 M), require compensa-
tion for the thinner air (less volume of air per cubic foot).
Higher altitudes affect the atmospheric pressure and heat
value of gaseous fuels. The lower oxygen content in the
air and the lower gas viscosity require the use of a differ-
ent orifice to achieve efficient, clean combustion at the
burner tube.
For high altitude installations consult the local gas
distributor or the authority having jurisdiction for proper
rating methods. If the installer must convert the unit to
adjust for varying altitudes, use Jøtul High Altitude Kit,
#155810-NG.
DO NOT DERATE THE BURNER FOR PROPANE.
In the U.S: THE DERATING KIT MUST BE INSTALLED BY
AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL
CODES AND REQUIREMENTS OF THE AUTHORITY HAV-
ING JURISDICTION. THE INFORMATION STICKER MUST
BE COMPLETED BY THE INSTALLER AND APPLIED TO THE
APPLIANCE AT THE TIME OF THE CONVERSION. THE QUALI-
FIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS DERATING.
In Canada: This unit has been tested for installation at
high altitudes in accordance with Canadian test standard
CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1
AND .2 INSTALLATION CODE.
AVERTISEMENT:
Cet equipement de conversion sera installe par une
agence qualkfiee de service conformenment aux instruc-
tions du fabricant et toutes exigences et codes apple-
cables de l'autorises avoir la juridiction. Si l'informaiton
dans cette Instruction n'est pas suivie exactement, un
feu, explosion ou production de protoxyde de carbone
peut resulter le dommages causer de propriete, perte ou
blessure personnelle de vie. L'agence qualifiee' de service
est esponsable de l'installation propre de cet equipe-
ment. L'installation n'est pas propre et complete jusqu'a
l'operation de l'appareil converti est cheque suivant les
criteres etablis dans les instructions de proprietaire provi-
sionnees avec l'equipement.
Derating Procedure
1. Follow Steps 1-10 of the Fuel Conversion procedure
outlined on pages 11 and 12.
2. Replace the original orifice with the #40 orifice in the kit.
3. Fill out the high altitude conversion label from the kit
and attach to the rating plate or gas valve.
4. Reassemble the firebox components.
5. It may be necessary to adjust the air shutter on the
burner tube. See AIR SHUTTER/FLAME APPEARANCE on
page 16 for more details.
Figure 43. Change the Burner Orifice.

Mobile Home Installation

The GF 300 BV can be installed for use in a mobile home
in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.
Use Jøtul Floor Bracket Kit #750304.
2. Provision must be made to secure an electrical ground
between the stove and the mobile home chassis.
3. The stove is installed in accordance with Title 24 CFR,
Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with CSA
Z240.4, Gas Equipped Recreational Vehicles and Mobile
Housing.
4. Always contact your local officials about installation
restrictions and requirements in your area.
THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLA-
TION IN A MANUFACTURED (MOBILE) HOME AND MUST
BE INSTALLED IN ACCORDANCE WITH THE MANUFAC-
TURER'S INSTRUCTIONS AND THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,
PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE
TYPE OF GAS THAT IS INDICATED ON THE STOVE'S RATING
PLATE. A GAS CONVERSION KIT IS PROVIDED WITH THE GF
300 DV GAS STOVE.
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR-
KET PERMANENTLY LOCATED, MANUFACTURED (MOBILE)
HOME, WHERE NOT PROHIBITED BY LOCAL CODES.
CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON
PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI
LES REGLEMENTS LOCAUX LE PERMETTENT. CET APPAR-
EIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE
GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE. NE PAS
L'UTILISER AVEC D'AUTRES GAS SAUF SI UN KITDE CON-
VERSION CERTIFIE EST INSTALLE.
137945_Rev_F 7.29.10
Replace with #40
orifice
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf 300 bv

Table of Contents