Wall Thermostat; Remote Control; Log Set Installation - Jøtul GF 100 DV II Nordic QT; GF 200 DV II Lillehammer Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

138003_Rev_K / 7.29.10
Optional Wall Thermostat or

Remote Control

Use only a 750 millivolt DC two-wire circuit thermostat
with this appliance. The thermostat should be placed
in the same room as the heater, typically 5 feet off the
floor. Avoid drafty areas or any area that may affect the
accuracy of the thermostat.
The thermostat should be connected to the Nordic
QT using a minimum of 16 gauge wire with a maximum
length of 35 feet of wire.
Connect the two thermostat wire leads to the two
lower terminals on the terminal block located directly to
the right of the valve. Do not overtighten the connec-
tions. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER
WIRES. See Fig. 27.
For thermostatic operation, the On/Off/T-Stat switch
on the back of the stove must be in the T-stat position,
and the pilot light must be running, as it is the power
source for the thermostat.
At the thermostat, the two wires should be connect-
ed to the two connection screws on the thermostat base
plate per the manufacturer's instructions.
Remote Control
When using a remote, the remote receiver should be
wired to the terminal block the same way the thermo-
stat would be. See the instructions above.
Follow the operating instructions included with the
Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER OR DANGEROUS OPERATION. ALWAYS VERIFY
PROPER OPERATION AFTER SERVICING THE APPLIANCE.
THERMOPILE
TH
TP
TH
TP
VALVE
Figure 27. Accessory wiring diagram.
20
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
TERMINAL
BLOCK

Log Set Installation

NOTE: Install the optional Brick Kit, if appropriate, before
installing the Log Set. See page 30.
The Log Set and Ember Stones are packaged in foam
inside the firebox. Wear gloves to prevent skin irritation
from the ceramic fibers.
1. Assemble the Left and Right Rear Logs as shown in
fig 28. First engage the halves together, and then
engage the pins on the burner skirt with the adjacent
holes in the underside of the logs.
2. Locate the Middle Log as shown in fig. 29.
3. Also included is a bag of ember stones that simulate
glowing coals when the burner is operating. These
should be spread thinly over the burner plate.
NOTE: Keep the ember stones 1/4" away from the edge
of the Burner Skirt an d Pilot Assembly. See fig. 29.
All the ember stones do not have to be used.
Figure 28.
Install
Rear Log.
KEEP EMBER STONES FROM
OBSTRUCTING PILOT AREA.
Figure 29. Middle Log and ember stones in place.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf 200 dv ii lillehammerGf 200 dv ii

Table of Contents