High Altitude Adjustment
Installations burning natural gas and located at altitudes
from 2000 - 4500 ft. (610 M - 1370 M), require compensa-
tion for the thinner air (less volume of air per cubic foot).
Higher altitudes affect the atmospheric pressure and heat
value of gaseous fuels. The lower oxygen content in the
air and the lower gas viscosity require the use of a differ-
ent orifice to achieve efficient, clean combustion at the
burner tube. For high altitude installations, consult the
local gas distributor or the authority having jurisdiction
for proper rating methods. If the installer must convert
the unit to adjust for varying altitudes, use Jøtul High
Altitude Kit, #155885-LP or # 155895 NG.
DO NOT DERATE THE BURNER FOR PROPANE.
In the U.S: THE DERATING KIT MUST BE INSTALLED BY
AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL
CODES AND REQUIREMENTS OF THE AUTHORITY HAV-
ING JURISDICTION. THE INFORMATION STICKER MUST
BE COMPLETED BY THE INSTALLER AND APPLIED TO THE
APPLIANCE AT THE TIME OF THE CONVERSION. THE QUALI-
FIED SERVICE AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS DERATING.
In Canada: This unit has been tested for installation at
high altitudes in accordance with Canadian test standard
CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1
AND .2 INSTALLATION CODE.
AVERTISEMENT:
CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR
UNE AGENCE QUALKFIEE DE SERVICE CONFORMENMENT
AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES
ET CODES APPLECABLES DE L'AUTORISES AVOIR LA JURI-
DICTION. SI L'INFORMAITON DANS CETTE INSTRUCTION
N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU
PRODUCTION DE PROTOXYDE DE CARBONE PEUT RE-
SULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU
BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIEE' DE
SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE
CET EQUIPEMENT. L'INSTALLATION N'EST PAS PROPRE ET
COMPLETE JUSQU'A L'OPERATION DE L'APPAREIL CONVERTI
EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES
INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC
L'EQUIPEMENT.
Derating Procedure
1. Follow Steps 1-10 of the Fuel Conversion procedure
outlined on pages 11 and 12.
2. Replace the original orifice with the appropriate orifice
in the kit: 3.10 mm NG or #51 LP.
3. Fill out the high altitude conversion label from the kit
and attach to the rating plate or gas valve.
4. Reassemble the firebox components.
5. It may be necessary to adjust the air shutter on the
burner tube. See AIR SHUTTER/FLAME APPEARANCE on
page 16 for more details.
Air Shutter
Wingnut
OPEN
CLOSED
FRONT
LEG
Air Shutter
Burner Plate

Mobile Home Installation

The GF 400 BV can be installed for use in a mobile home
in the U.S. and Canada provided:
1. The stove is secured to the floor of the mobile home.
Use Jøtul Floor Bracket Kit #750304.
2. Provision must be made to secure an electrical ground
between the stove and the mobile home chassis.
3. The stove is installed in accordance with Title 24 CFR,
Part 3280- Manufactured Home Construction and
Safety Standard, in the U.S. In Canada, comply with CSA
Z240.4, Gas Equipped Recreational Vehicles and Mobile
Housing.
4. Always contact your local officials about installation
restrictions and requirements in your area.
THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLA-
TION IN A MANUFACTURED (MOBILE) HOME AND MUST
BE INSTALLED IN ACCORDANCE WITH THE MANUFAC-
TURER'S INSTRUCTIONS AND THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR,
PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE
TYPE OF GAS THAT IS INDICATED ON THE STOVE'S RATING
PLATE. A GAS CONVERSION KIT IS PROVIDED WITH THE GF
300 DV GAS STOVE.
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMAR-
KET PERMANENTLY LOCATED, MANUFACTURED (MOBILE)
HOME, WHERE NOT PROHIBITED BY LOCAL CODES.
CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON
PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI
LES REGLEMENTS LOCAUX LE PERMETTENT. CET APPAR-
EIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE
GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE. NE PAS
L'UTILISER AVEC D'AUTRES GAS SAUF SI UN KITDE CON-
VERSION CERTIFIE EST INSTALLE.
138301_Rev_G 10.4.11
Figure 51. Locate
and remove
the Air Shutter
wingnut from
under the right
side of the stove.
BACK
LEG
Figure 52.
Remove the
Air Shutter
and Burner as
a unit.