7.4.1.2 System Alarm Actions, Continued
b. Use the number buttons to change the camera number, preset and alarm timer
c. If no item is to be changed or you've completed setting up the alarms, press the
7.4.1.3 Contact Tables
This feature is not functional at this time.
7.4.1.4 Messages
This feature is not functional at this time.
7.4.2 Camera Alarms
This feature is not functional at this time.
7.4.3 Alarm Properties
The operation of the alarms can be defined and the audible alarm buzzer can be
enabled or disabled.
1. From the System Alarms Menus, press
the 3 button.
a. Move the joystick up or down to
2. The alarms can be set so they are active from the time the alarm is activated and
then for the defined timer amount programmed in the Systems Alarms Setting Menu
or active only for the defined timer setting.
Rev. 1
associated with each alarm input.
Any camera, preset, and timer can be selected for each alarm. The camera
number range is from 1 to the maximum number of cameras connected to the
MaxCom Gold. The preset range is from 0 to 127. The timer range is 0 to 255
(seconds). If the alarm time = 0, then the alarm will be active only for the
duration of the active alarm input. This option can be used, for example, with
sensors that have built in alarm timers.
Relay - This option allows a camera head relay output to be triggered on an
incoming alarm to the MaxCom. Options are camera, followed by relay number -
for instance an entry of 03-01 with trigger relay 1 on camera 3.
lock button to return to the System Alarms Menu.
move to between the settings. When
a setting is flashing, pressing the aux
button toggles between the available
options for that setting.
ACTIVE FOR CONTACT THEN TIMER
37
ALARM PROPERTIES
EQUAL PRIORITY CAN INTERRUPT
PRE-ALARM POSITION RETURNED
ALARM BUZZER ENABLED
AUX TO CHANGE
LOCK TO EXIT