Installing An 808A Emergency Transfer Panel And Associated Telephones - Avaya G700 Installation Manual

Media gateway and media server
Hide thumbs Also See for G700:
Table of Contents

Advertisement

Connecting telephones and adjunct systems
4. Install cross-connect jumpers to connect the pins from the 2-wire digital station to the
appropriate pins on the MM711 Media Module.
stations.
Table 18: Two-Wire Station Pinout Chart
Jack Name
BRI-T
ADJUNCT
DSS (QUEST)
DSS (ISDN)
BRI-A
BRI-U
DCP
ANALOG
HANDSET
5. Administer using Administrator's Guide for Avaya Communication Manager.
Figure 18: 2500-Type Analog Telephone Wiring
Figure notes:
1. 2500-Type Analog Station
Installing an 808A Emergency Transfer Panel and
associated telephones
Note:
Install only 1 emergency transfer power panel per system.
Note:
Emergency transfer capability is provided by an 808A Emergency Transfer Panel (or
equivalent) mounted next to the trunk/auxiliary field. See
Panel
on page 387.
386 Installation and Upgrades for Avaya G700 Media Gateway and Avaya S8300 Media Server
1
2
3
+TX
+Vadj
T0
-V
DTX
DRX
GND
TX1
TX2
RX1
-TX
T
2
3
R
2. MM711 Analog Media Module, Position 1V301
Table 18
shows a pinout chart for two-wire
4
5
+RX
-RX
GNDVoice
RRVoice
TX
RX
TX
RX
TIP
RING
+RX
-RX
28
T.3
03
R.3
2500wire RBP 071996
Figure 19: 808A Emergency Transfer
6
7
8
-TX
-V
GND
+V
S0
TTVoice
OKdig
-V
+V
-V
-V
GND
RX2
-V
+V
+TX

Advertisement