D D Rear panel— 2
External Display
RX ANT
OUT
[METER]
Connects an external meter, etc.
Output impedance
Output voltage (open circuit) : 2.5 V (default)
Output voltage can be adjusted 0 to 5 V
in ACC set mode (p. 12-8)
[DC OUT]
Outputs regulated 14 V
(approx.) DC for external
equipment power supply.
(max. 1 A capacity)
Connects a PC-style
monitor display (at least
800×600 resolution).
Video output signal can
be turned ON and OFF
in set mode (p. 12-11)
ANT 1
ANT 2
DC OUT
EXT
15V
KEYPAD
IN
X-VERTER
MAX1A
METER
3.5 (d) mm; 1⁄8" plug
: 4.7 kΩ
External keypad
Connects an external keypad for direct voice memory
and memory keyer controls.
INSTALLATION AND CONNECTIONS
Ethernet connector (p. 16-6)
ANT 3
ANT 4
ACC
EXT - SP
2
1
RELAY
[S/P DIF IN/OUT]
Connects a PC for audio sig-
nal data (48 kHz, 16-bit) in-
put/output.
EXTERNAL KEYPAD
1.5 kΩ
3.5 (d) mm; 1⁄8" plug
±5%
S1
(T1/M1)
Mute switch: Mutes both transmission and
reception when switched ON during trans-
ceive operation, etc.
2-7
Connects a PC
via a LAN for the
CPU
firmware
update.
EXT-DISPLAY
REMOTE
RS-232C
AC
I
15A
GND
REF I/O
ALC
S/P DIF
10MHz
CW KEY
-10dBm
ALC
ADJ
OUT
IN
1.5 kΩ
2.2 kΩ
4.7 kΩ
±5%
±5%
±5%
S2
S3
S4
(T2/M2)
(T3/M3)
(T4/M4)
2