Icom IC-7700 Instruction Manual page 193

Hf/50 mhz transceiver
Hide thumbs Also See for IC-7700:
Table of Contents

Advertisement

D D Command table (continued)
Command
Sub command
1A
050023
050024
050025
050026
050027
050028
050029
050030
050031
050032
050033
050034
050035
050036
050037
050038
050039
050040
050041
050042
050043
050044
050045
050046
050047
050048
Description
Send/read CW side tone gain
(0=min. to 255=max.)
Send/read CW side tone gain limit
(0=OFF, 1=ON)
Send/read beep gain
(0=min. to 255=max.)
Send/read beep gain limit
(0=OFF, 1=ON)
Send/read headphones output
ratio (0=0.60 to 255=1.40)
Send/read AF output level to ACC
(0=0% to 255=100%)
Send/read S/P DIF output level
(0=0% to 255=100%)
Send/read MOD output level to
ACC (0=0% to 255=100%)
Send/read S/P DIF MOD output
level (0=0% to 255=100%)
Send/read MOD input connector
during DATA OFF (0=MIC;
1=ACC; 2=MIC/ACC; 3=S/P DIF)
Send/read MOD input connector
during DATA1
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
Send/read MOD input connector
during DATA2
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
Send/read MOD input connector
during DATA3
(0=MIC; 1=ACC; 2=MIC/ACC;
3=S/P DIF)
Send/read relay type selection
(0=Lead, 1=MOS-FET)
Send/read external meter output
selection
(0=Auto, 1=S, 2=Po, 3=SWR,
4=ALC, 5=COMP, 6=V
, 7=I
D
Send/read external meter output
level (0=0% to 255=100%)
Send/read reference signal in/out
setting (0=IN, 1=OFF, 2=OUT)
Send/read reference signal fre-
quency setting
(0=0% to 255=100%)
Send/read LCD unit backlight
brightness (0=0% to 255=100%)
Send/read switch indicator bright-
ness (0=0% to 255=100%)
Send/read screen image type
(0=A, 1=B)
Send/read frequency readout font
(0=Basic (1), 1=Basic (2), 2=Italic,
3=Round, 4=Slim)
Send/read meter response setting
(0=SLOW, 1=MID, 2=FAST)
Send/read meter type
(0=Standard, 1=Edgewise, 2=Bar)
Send/read meter type during wide
screen or mini scope indication
(0=Edgewise, 1=Bar)
Send/read peak hold set for Bar
meter (0=OFF, 1=ON)
Command
Sub command
1A
)
D
14-5
CONTROL COMMAND
Description
050049
Send/read memory name indica-
tion setting (0=OFF, 1=ON)
050050
Send/read audio peak filter width
pop-up indication setting
(0=OFF, 1=ON)
050051
Send/read manual notch width
pop-up indication setting
(0=OFF, 1=ON)
050052
Send/read screen saver set
(0=OFF, 1=15 min., 2=30 min.,
3=60 min.)
050053
Set/read screen saver type
(0=Bound, 1=Rotation, 2=Twist)
050054
Send/read output signal setting for
external display (0=OFF, 1=ON)
050055
Send/read synchronous pulse
level setting (0=L, 1=H)
050056
Send/read opening message indi-
cation (0=OFF, 1=ON)
050057
Send/read opening message con-
tents (see p. 14-9 for details)
050058
Send/read date
(20000101=1st Jan. 2000 to
20991231=31st Dec. 2099)
050059
Send/read time
(0000=00:00 to 2359=23:59)
050060
Send/read CLOCK2 function
(0=OFF, 1=ON)
050061
Send/read offset time for CLOCK2
(240001=–24:00 to
240000=+24:00)
050062
Send/read CLOCK2 name
(up to 3-character; see p. 14-9)
050063
Send/read calibration marker
(0=OFF, 1=ON)
050064
Send/read confirmation beep
(0=OFF, 1=ON)
050065
Send/read band edge beep
(0=OFF, 1=ON)
050066
Send/read beep audio frequency
(50=500 Hz to 200=2000 Hz)
050067
Send/read quick split set
(0=OFF, 1=ON)
050068
Send/read FM split offset –9.999
to +9.999 MHz for HF
(see p. 14-10 for details)
050069
Send/read FM split offset –9.999
to +9.999 MHz for 50 MHz
(see p. 14-10 for details)
050070
Send/read split lock set
(0=OFF, 1=ON)
050071
Send/read tuner auto start set
(0=OFF, 1=ON)
050072
Send/read PTT tune set
(0=OFF, 1=ON)
050073
Send/read transverter set
(0=OFF, 1=ON)
050074
Send/read transverter offset
(see p. 14-10 for details)
050075
Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
050076
Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)
14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents