Timer Vector Register; Bus Timeout Period Register - Motorola MC68306 User Manual

Integrated ec000 processor
Table of Contents

Advertisement

DUIPL2–0—DUART Interrupt Priority Level
This bit selects the interrupt priority level for the serial module.
000 = Reserved
001 = Interrupt priority level 1
010 = Interrupt priority level 2
011 = Interrupt priority level 3
100 = Interrupt priority level 4
101 = Interrupt priority level 5
110 = Interrupt priority level 6
111 = Interrupt priority level 7

5.2.2 Timer Vector Register

TVEC7–0—Timer Vector
The value set in this field supplies the vector for the DUART timer interrupt handler.

5.2.3 Bus Timeout Period Register

A programmable-period timer can generate a bus error to terminate any bus cycle after 16
to 4096 wait states, programmable in 16-wait state increments. The bus timeout timer is
enabled by the BTEN bit in the system register.
The bus timeout timer restarts between the read and write portions of a TAS indivisible
cycle.
BT7–0—Bus Timeout Period
The value set in this field supplies the bus timeout timer period. The bus timeout timer
period can be calculated from the equation:
Period = (16
(register value +1))
5-4
FFFFFFFF
7
6
5
TVEC
TVEC
TVEC
TVEC
7
6
5
RESE
T:
0
0
0
FFFFFFFC
7
6
5
BT7
BT6
BT5
BT4
RESE
T:
U
U
U
EXTAL
MC68306 USER'S MANUAL
4
3
2
1
TVEC
TVEC
TVEC
4
3
2
1
0
1
1
1
SUPERVISOR ONLY
4
3
2
1
BT3
BT2
BT1
U
U
U
U
SUPERVISOR ONLY
0
TVEC
0
1
0
BT0
U
MOTOROLA