Use the CURSOR button (jldc) to
shift the position of the central light
sensing zone.
The zone can be moved up or down and left
or right.
Note:
If the zone fills the right side it will become
smaller.
If the zone fills the bottom side it will become
smaller.
3
Press the SET button.
The BLC SETTING (SIZE) screen will
appear.
4
Use the CURSOR button (jldc) to
adjust the size of the central light sensing
zone.
The zone can be moved up or down and left
or right.
5
Press the SET button.
The BLC WINDOW WEIGHTING screen will
appear.
6
Use the CURSOR button (j or l) to
select a zone, then use the CURSOR
button (d or c) to adjust weighting.
The weighting for each zone except for the
CENTER zone can be adjusted within the
range 0 – 7.
TOP: Weighting is at top.
BOTTOM: Weighting is at bottom.
LEFT: Weighting is at left.
RIGHT: Weighting is at right.
CENTER (FIX): Center weighting is fixed by
Note: If this is set to "0", the light intensity will
be ignored. The larger the setting value,
the greater is the weighting given to light
coming from the respective side.
To return the settings in this screen to their
defaults, change PRESET to ON and then
press the SET button.
To close the menu screen or return to the
previous screen, select BACK or END for
MENU and press the SET button.
3
MASK (48 multi-spot metering):
Measures light mainly at the center and corrects
according to the best image obtained.
1
Use the CURSOR button (jldc) to
select MASK for BLC, then press the SET
button.
The BLC MASKING screen will appear.
28