Using the alarm function
If a device with an alarm function that uses a
lamp or buzzer is connected to the camera, the
zoom ratio can be increased when an intruder is
detected. In addition, the DAY/NIGHT
(color/black & white) mode can also be selected.
However, only either the alarm function or the
mode selection function can be used at once
time. For either function, the settings in the
ALARM SETTING screen must be made.
(See p39)
GRAY/BLACK (ALARM IN) cord:
This cord is used to input alarm signals or
DAY/NIGHT signals to the camera. The
alarm function for the connected device must
be set correctly. Refer to the Instruction
Manual for the connected device for further
details.
BLUE (ALARM OUT) cord:
This cord is used to output alarm signals
from the camera. When the alarm function is
on, a buzzer or lamp can give a warning
when an intruder is detected.
Output rating: max. 18V, 25mA
(open collector, emitter
grounded)
GRAY/BLACK (ALARM IN) cord
BLUE (ALARM IN) cord
BROWN (GND) cord *
External alarm signal
Buzzer or Lamp, etc.
Ground
D
Using a system controller
When the camera is connected to the RS-485
terminal of a system controller, more than one
camera can be controlled at the same time.
Refer to the Instruction Manual for the system
controller for further details.
GRAY (RS485 (A)) cord:
Connect to the RS-485 A terminal of the
system controller.
ORANGE/BLACK (RS485 (B)) cord:
Connect to the RS-485 B terminal of the
system controller.
GRAY (RS485(A)) cord
ORANGE/BLACK (RS485(B)) cord
One-touch
connector
(accessory)**
BROWN (GND) cord *
** Connection is also possible if the one-touch
connector is removed. The one-touch
connector can be used on other cords after it
has been removed.
10
System controller
RS485A
RS485B
Ground