Dot1X Url - HP 6125G Command Reference Manual

Security command reference
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Parameters
ead-timeout-value: Specifies the EAD rule timer in minutes, in the range of 1 to 1440.
Description
Use dot1x timer ead-timeout to set the EAD rule timer.
Use undo dot1x timer ead-timeout to restore the default.
By default, the timer is 30 minutes.
EAD fast deployment automatically creates an ACL rule, or EAD rule, to open access to the redirect URL
for each redirected user seeking to access the network. The EAD rule timer sets the lifetime of each ACL
rule. When the timer expires or the user passes authentication, the rule is removed. If users fail to
download EAD client or pass authentication before the timer expires, they must reconnect to the network
to access the free IP.
To prevent ACL rule resources from being used up, you can shorten the timer when the amount of EAD
users is large.
Related commands: display dot1x.
Examples
# Set the EAD rule timer to 5 minutes.
<Sysname> system-view
[Sysname] dot1x timer ead-timeout 5

dot1x url

Syntax
dot1x url url-string
undo dot1x url
View
System view
Default level
2: System level
Parameters
url-string: Specifies the redirect URL, a case-sensitive string of 1 to 64 characters in the format
http://string.
Description
Use dot1x url to configure a redirect URL. When a user uses a web browser to access networks other
than the free IP, the device redirects the user to the redirect URL.
Use undo dot1x url to remove the redirect URL.
By default, no redirect URL is defined.
The redirect URL must be on the free IP subnet.
If you configure the dot1x url command multiple times, the last configured URL takes effect.
Related commands: display dot1x and dot1x free-ip.
113

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125 blade switch series

Table of Contents