Filter Plate; Motor Rotor - Fisher & Paykel DishDrawer DD247 Service Manual

Dishdrawer
Table of Contents

Advertisement

62

9.11 Filter Plate

Remove the cutlery basket and rack from the tub.
1.
Remove the drain filter assembly.
2.
Rotate the filter plate locknut anti-clockwise to release
3.
the filter plate from the motor rotor assembly.
Lift the filter plate clear.
4.
Refit in reverse manner, ensure the 3 legs are locked
5.
correctly to the motor rotor and the o-ring on top of
the motor rotor is in place.

9.12 Motor Rotor

Remove the filter plate (refer section 9.11)
1.
Slightly lift the motor rotor lock ring at the pointer
2.
to disengage the lock tab under the chimney, then
rotate the motor rotor anti-clockwise to release it
from the motor housing and lift out.
The rotor assembly is not serviceable and if damaged
3.
should be replaced.
Refit in reverse manner, taking care to align the legs
4.
on the rotor with the slots in the motor housing. The
rotor can only be placed in one position. The short leg
goes into the middle slot on the housing.
Locknut
Motor Rotor
Rotate
Direction
Lock Tab
D
O-Ring
Pointer

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dishdrawer dd607

Table of Contents