SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or open the circuit Installation of this dishwasher requires basic mechanical and electrical skills. ● breaker. If permanently connecting the dishwasher, be sure the power is Be sure to leave these Instructions with the Customer.
PARTS SUPPLIED Drain hose Drain hose Wire clip (2) Clamp (1) Side mounting support (1) joiner (1) (for securing (for securing bracket kit mounting Drain hose joiner) Drain hose joiner) (A and B) (2) brackets (2) OPTIONAL OPTIONAL Edge Protector (1) Phillips Rubber washer Moisture protection...
Page 4
OPTIONALLY HARD WIRING PRIOR TO INSTALLATION REMOVE THE LOWER DRAWER REMOVE THE ACCESS COVER & REMOVE POWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.
Page 5
OPTIONALLY HARD WIRING PRIOR TO INSTALLATION TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS Fit a suitable cable clamp for the conduit through the metal knockout. Ensure wiring is routed through or under under housing ribs. Screw down the Live, Neutral and Earth wires correctly.
Bracket slots PLAN STANDARD TALL PROFILE HEIGHT HEIGHT MODELS MODELS DD24DTI DD24DI DD24DHTI CABINETRY DIMENSIONS INCHES (MM) INCHES (MM) Minimum clearances from adjacent cabinetry Inside height of cavity* min. 32 5/16” (820) min. 34” (864) Inside width of cavity 23 5/8” (600) 23 5/8”...
Page 8
(23 7/16”-24 3/16” (596-615mm)) HEIGHT OF THE UPPER PANEL HEIGHT OF UPPER PANEL Minimum height UPPER PANEL HEIGHT OF UPPER PANEL DD24DI models: Upper Panel extension 15 11/16” (398mm) DD24DTI/DD24DHTI models: (442mm) 17 3/8” (0”/0mm recommended) Note: The ‘upper panel extension’ B allows for the top of the upper Ventilation Gap (min.
Page 9
Upper Panel toekick panel TOEKICK PANEL extension Clearance to floor mounting point Depth is measured from FRONT of door panel DD24DI models: (assuming thickness ~ 11/16” (18mm) to front Toekick Depth face of custom toekick label (750mm) 29 1/2” (0”/0mm (min.
CAVITY PREPARATION IMPORTANT! The power outlet COUNTERTOP must be located in a cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A Moisture 3/8” Water Connection protection (10 mm) tape must Recommended HOT be applied. (Maximum 140°F/60°C). Supplied hose to suit 3⁄8”...
Page 11
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hoses - 78 1/2” (2000mm) Drain hoses - 70 1/2” (1800mm) Inlet hose - 64 3/4” (1650mm) Inlet hose - 49” (1250mm) Power cord (excl.plug) - 29 1/2” (750mm) Power cord (excl.plug) - 27 1/2”...
Page 12
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) ATTACH SIDE MOUNTING BRACKETS PULL THROUGH HOSES & PUSH INTO THE CAVITY optionally attach the Clip all four side mounting brackets When fitting brackets, into their slots using a flat-bladed...
Page 13
SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE The top mounting Open the brackets will only drawer halfway. (x2) bend upwards a Using a flat maximum of 3⁄8” bladed (10 mm). Replace the gray screwdriver, rubber plug back into prise the gray the trim moulding...
Page 14
ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL PULL THROUGH HOSES & PUSH INTO THE CAVITY REMOVE THE LOWER DRAWER To prevent kinked hoses optionally attach the Either sit the drawer down on the left two top mounting When fitting brackets, hand side (recommended) or rotate the brackets ensure the ends are...
Page 15
SECURE TO THE CABINETRY ON THE SIDES OPTIONALLY SECURE TO THE CABINETRY ABOVE The top mounting brackets will only (x2) bend upwards a maximum of 3⁄8” For further adjustment, (10 mm). using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand.
Page 16
INSTALLING CUSTOM FRONT DRAWER PANELS REMOVE BOTH PANEL BRACKETS FROM PRODUCT REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Knock-to-Pause module Before continuing, ensure that the product is disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire.
Page 17
INSTALLING CUSTOM FRONT DRAWER PANELS ATTACH KNOCK-TO-PAUSE MODULES ATTACH CUSTOM PANELS TO PANEL BRACKETS TO CUSTOM PANELS There must be at least 3 screws used each side. Align bottom of each custom panel with the bottom of each bracket. 5/8” (16mm) IMPORTANT! (x3) Ensure the Knock-To-Pause...
Page 18
INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE RECONNECT THE EARTH WIRE TO THE TO THE CONTROLLER PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g.
Page 19
FITTING A CUSTOM TOEKICK PANEL Custom Toekick Panel Place the Toekick mounting bracket cutting template onto your toekick panel. Ensure they are centered and the template rests on the top surface of the panel. Secure template to panel either by clamping or using the supplied mounting screws.
Page 20
FIT THE SUPPLIED PREFINISHED TOEKICK PANEL (IF PREFERRED) Prefinished Toekick Panel Where the toekick meets the bottom of the tub is the cut-off point Lay the toekick face down on Turn the toekick over and Smooth the edge with a file. a chopping board or similiar score along the same line Be careful of sharp edges.
Page 21
THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 1 1/2” (38 mm) Standpipe Screw Drain hose support to back wall at correct height If space is limited for fixing, push hose through drain hose support to required height...
Page 22
DRAINAGE OPTION 2 Dishwasher using Air Break with Drain Hose Joiner Secure both drain hoses to drain hose joiner and secure to Air Break 37 3/8” (950 mm) Max. height to top of Air Break (countertop or wall mounted) step 18 min.
Page 23
DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall Supplied drain at correct height hose joiner to suit Ø 3/4” (19 mm) If space is limited waste tee for fixing, push hose through drain hose support to required height...
CONNECT INLET HOSE TO HOT WATER SWITCH PRODUCT ON No leaks! Ensure the supplied Tighten coupling rubber washer is with spanner. fitted inside the coupling. TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) ●...
FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Turn on the power and water supplies, then open the drawers. You should hear a Check all parts are installed. beep and see a program indicator light up on the internal control panel. Ensure that all panels and parts thereof are secure and final electrical tests have been Check the spray arms are in place, mounted correctly and free to rotate, by conducted in accordance with local electrical regulations.
Page 26
SINGLE DISHDRAWER DISHWASHER DD24SI, DD24STI & DD24SHTI models INSTALLATION GUIDE US CA 591386 A 08.17...
Page 27
SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS WARNING! Electrical Shock Hazard Before installing the dishwasher, remove the house fuse or open the circuit Installation of this dishwasher requires basic mechanical and electrical skills. ● breaker. If permanently connecting the dishwasher, be sure the power is Be sure to leave these Instructions with the Customer.
Page 28
PARTS SUPPLIED Drain hose Drain hose Wire clip (1) Clamp (1) Side mounting support (1) joiner (1) (for securing (for securing bracket kit mounting Drain hose joiner) Drain hose joiner) (A and B) (2) brackets (2) OPTIONAL OPTIONAL Phillips 38 mm Rubber washer Moisture protection Cavity Bracket Kit (1)
Page 29
OPTIONALLY HARD WIRING PRIOR TO INSTALLATION REMOVE THE DRAWER REMOVE THE ACCESS COVER & REMOVE POWER To prevent kinked hoses Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.
Page 30
OPTIONALLY HARD WIRING PRIOR TO INSTALLATION TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS Fit a suitable cable clamp for the conduit through the metal knockout. Ensure wiring is routed through or under under housing ribs. Screw down the Live, Neutral and Earth wires correctly.
Page 31
PRODUCT DIMENSIONS FRONT PROFILE STANDARD TALL HEIGHT HEIGHT MODELS MODELS DD24STI DD24SI DD24SHTI PRODUCT DIMENSIONS INCHES (MM) INCHES (MM) Overall height of product 16 1/8” (410) min. 17 7/8” (454) Overall width of product 23 9/16” (599) 23 9/16” (599) Overall depth of product 22 1/2”...
Page 32
CABINETRY DIMENSIONS Bracket slots PLAN STANDARD TALL HEIGHT HEIGHT MODELS MODELS DD24STI PROFILE DD24SI DD24SHTI CABINETRY DIMENSIONS INCHES (MM) INCHES (MM) Custom Filler Panel Inside height of cavity min. 16 1/4” (412) min. 18” (456) Inside width of cavity 23 5/8” (600) 23 5/8”...
Page 33
CUSTOM DRAWER PANEL SPECIFICATIONS FRONT PANEL MATERIAL SPECIFICATIONS 1/16” (2mm) 5/8 - 13/16” (16 - 20mm) panel thickness ● Note: when the top of the dishwasher Adequately sealed to withstand moisture (122 F/50 C @ 80% RH) ● has to be lower than the adjacent Because of it being a hot and wet environment generally, the back and sides of the cabinetry, the top of the panel can panel should be completely sealed with a waterproof vapour barrier (ie polyurethane)
Page 34
CAVITY PREPARATION IMPORTANT! The power outlet must be located in a COUNTERTOP cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A Moisture 3/8” protection (10mm) tape must be applied. Water Connection Recommended HOT These marks indicate (Maximum 140°F/60°C). formed bracket screw locations, if Supplied hose to suit...
Page 35
PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET External Venting Kit Shelf cutouts max. 3⁄16” (5mm) VENT HOSE ø max. 1 1⁄2” ø 2 3⁄8” Services can be located ø 2 3⁄8” (38mm) (60mm) either side of dishwasher (60mm) IMPORTANT! To prevent pooling of condensation from the DRAIN HOSE + 8 11⁄16”...
Page 36
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE LEFT HAND SIDE RIGHT HAND SIDE Drain hose - 70 1/2” (1800mm) Drain hose - 78 1/2” (2000mm) Inlet hose - 49” (1250mm) Inlet hose - 64 3/4” (1650mm) Power cord (excl.plug) - 29 1/2” (750mm) Power cord (excl.plug) - 27 1/2”...
Page 37
NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B) IS MORE SUITABLE FOR YOUR CABINETRY... RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY) ATTACH SIDE MOUNTING BRACKETS ATTACH VENTING HOSE Clip all four side mounting brackets into their slots using a flat-bladed screwdriver.
Page 38
PULL THROUGH HOSES & MOVE INTO THE CAVITY SECURE TO THE CABINETRY ON THE SIDES Open the drawer halfway. Using a flat bladed Replace the gray screwdriver, rubber plug back into prise the gray the trim moulding rubber plug out and ensure the trim of the trim seal is facing forward.
Page 39
ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL ATTACH VENTING HOSE PULL THROUGH HOSES & MOVE INTO THE CAVITY Check that the fitted elbow is rotated left or right (depending on the direction of the routing), then ensure the venting hose is securely attached to it.
Page 40
REMOVE THE DRAWER SECURE TO THE CABINETRY ON THE SIDES To prevent kinked hoses The product has three Either sit the drawer down on the left pairs of fixing points: hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.
Page 41
REFIT THE DRAWER ONTO THE RUNNERS Lift or rotate counter-clockwise the drawer back onto the drawer runners on either side. Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of Pull the release tabs forward on both each drawer runner are sides 4”...
Page 42
INSTALLING A CUSTOM FRONT DRAWER PANEL REMOVE PANEL BRACKET FROM PRODUCT REMOVE THE KNOCK-TO-PAUSE MODULE WARNING! Electrical Shock Hazard Before continuing, ensure that the product is Knock-to-Pause module disconnected from the power supply. Failure to follow this warning may result in electrical shock, injury or fire.
Page 43
INSTALLING CUSTOM FRONT DRAWER PANELS ATTACH KNOCK-TO-PAUSE MODULE ATTACH CUSTOM PANELS TO PANEL BRACKETS TO CUSTOM PANEL There must be at least 3 screws used each side. Align bottom of each custom panel with the bottom of each 16mm (x3) bracket.
Page 44
INSTALLING CUSTOM FRONT DRAWER PANELS CONNECT THE KNOCK-TO-PAUSE MODULE RECONNECT THE GROUND WIRE TO THE TO THE CONTROLLER PANEL BRACKET WARNING! Electrical Shock Hazard To earth the panel bracket, connect the earth wire from the product to one of the tabs. Any custom metal component (e.g.
Page 45
THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE. DRAINAGE OPTION 1 Dishwasher and Ø 1 1/2” (38 mm) Standpipe Screw Drain hose support to back wall at correct height If space is limited for fixing, push hose through drain hose support to required height...
Page 46
DRAINAGE OPTION 2 Dishwasher using Air Break with Drain Hose Joiner Secure drain hose to drain hose joiner and secure to Air Break 37 3/8” (950mm) Max. height to top of Air Break step 19 (countertop or wall mounted) min. R 8” (200mm) IMPORTANT! Ensure that drain...
Page 47
DRAINAGE OPTION 3 Dishwasher using drain hose joiner onto sink trap/waste tee Screw Drain hose support to back wall at correct height Supplied drain hose joiner to suit Ø 3/4” (19 mm) If space is limited waste tee for fixing, push hose through drain hose support to required height...
Page 48
CONNECT INLET HOSE TO HOT WATER SWITCH PRODUCT ON No leaks! Ensure the supplied Tighten coupling rubber washer is fitted inside the with spanner. coupling.
Page 49
TROUBLESHOOTING Excessive water remaining above the filter plate, after the rinse cycle. (This is displayed as an A3 fault. See user guide ‘How to attend to a fault’) ● Check for a kinked drain hose, blocked or incorrectly drilled out waste connection, highloop not properly installed, drain hose not routed correctly or spray arm not in place. No water supply.
Page 50
FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER Turn on the power and water supplies, then open the drawer. You should hear a Check all parts are installed. beep and see a program indicator light up on the control panel. Ensure that all panels and parts thereof are secure and final electrical tests have been Check the spray arms are in place, mounted correctly and free to rotate, by conducted in accordance with local electrical regulations.