Fault Code E6 -Fan Fault
Check the harness connections on the
1.
component and the controller for signs of any
water damage, corrosion or arcing. Replace if
damaged.
Check that the harness is securely connected at
2.
the controller.
Run the drying fan (dF) in "HO" mode (refer p30
3.
& 31) for at least 30 seconds. The fan should
push air through the vent. The flap within the
fan housing should open. To check if the flap is
free to move, remove the locking tab, remove
fan and the flap can be pushed upwards.
While running the fan is HO mode, if a long
4.
low tone is played at 1 second intervals this
indicates the fan is faulty, replace the fan.
Once the new fan is replaced, follow step 3 and
5.
run the fan in HO mode for 30 seconds, there
should be no tone played.
If the fan fault continues, replace the controller.
6.
Fault Code E6 - Sub Code 02 - Under Current
Check the harness connections at the controller
1.
Run the new drying fan (dF) in "HO" mode (refer p30 & 31) for at least 30 seconds. While running the
2.
fan in HO mode, if a long low tone is played at 1 second intervals this indicates the fan is faulty.
If the fault continues, replace the controller.
3.
Fault Code E6 - Sub Code 03 - Over Current
Run the new drying fan (dF) in "HO" mode (refer p30 & 31) for at least 30 seconds. While running
1.
the fan in HO mode, if a long low tone is played at 1 second intervals this indicates the fan is faulty.
If the fault continues, replace the controller.