THE CPL PROTOCOL
6 - 19
PROGRAM TEXT
PT
Purpose:
To program text to an oscilloscope.
If the S parameter is specified, setup text is programmed. The text will be set into
one of the setup registers of the oscilloscope. The parameter n specifies the setup
register. A maximum number of 22 characters is allowed. The remainder of the
text field is set to 'spaces'.
If the S parameter is not specified, user text is programmed. The text will be
displayed on the screen of the oscilloscope. A maximum number of 64 characters
is allowed. The remainder of the text field is set to 'spaces'. The parameter n may
not be used.
The programmed text can be read with the Query Text (QT) command.
Command 1:
"PT"
pds
"S"
pds
n
CR
Response 1:
acknowledge
CR
Command 2:
char
CR
Response 2:
acknowledge
CR