6 - 16
PROGRAM COMMUNICATION
Purpose:
To program baudrate, parity mode, number of data and stopbits and the
handshake method for computer communication.
After the command is sent, an <acknowledge> will be returned with the old
communication parameters still active.
If the <acknowledge> = 0, the new communication parameters will be valid
approximately 0.5 seconds later. The communication parameters are stored in
battery backup memory and restored on power-up.
This command performs the same function as the UTILITY + RS232 SETUP menu.
Command:
"PC"
pds
pds
<baud>
<parity>
<data bits>
<stopbits>
<handshake> = XONXOFF
baud
stop bits
pds
= 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200,
38400
= O, E or N
= 7 or 8
= 1
HWL
If left out, both handshake methods are disabled.
pds
parity
to bypass handshake
handshake
to enable Xon/Xoff handshake
to enable hardwareline handshake
THE CPL PROTOCOL
pds
data bits
CR
PC