Accessing The Tape Drive Backplane Of The M5000 Server - Fujitsu SPARC Enterprise M5000 Service Manual

Fujitsu server user manual
Hide thumbs Also See for SPARC Enterprise M5000:
Table of Contents

Advertisement

6.3.9
Accessing the Tape Drive Backplane of the M5000
Server
Caution – There is an electrical hazard if the power cords are not disconnected. All
power cords must be disconnected to completely remove power from the server.
Caution – Use proper ESD grounding techniques when handling components. See
Section 1.1, "Safety Precautions" on page
1. Power off the server.
This step includes turning the key switch to the Service position, confirming that
the POWER LED is off, and disconnecting power cables. See
"Powering the Server Off Using Software" on page
Caution – To prevent the equipment rack from tipping over, you must deploy the
antitilt feature, if applicable, before you slide the server out of the equipment rack.
Note – When drawing out the SPARC Enterprise M4000/M5000 Server to the front,
release the cable tie holding the PCI cables on the rear of the server.
2. Remove the top cover.
This step includes deploying the rack's antitilt features (if applicable), sliding the
server out of the equipment rack, and removing the top cover. See
"Removing the Top Cover" on page
Caution – The motherboard unit is heavy. Two people are recommended to lift the
unit. If the unit is too heavy the memory boards can be removed prior to lifting the
unit.
3. Remove the motherboard unit.
This step includes removing the CPU modules and filler panels, removing the
busbar screws, and removing the motherboard cradle. See
"Removing the M5000 Server Motherboard Unit" on page
1-1.
4-12.
5-5.
Chapter 6
Storage Devices Replacement
Section 4.4.1,
Section 5.2.1,
Section 13.1.6,
13-8.
6-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m4000

Table of Contents