4.2.12.5 Removing the PW Sensor
1.
Remove the Carriage Unit. (Refer to 4.2.9.)
2.
Release the hook of the PW Sensor Cover located on the Carriage Unit bottom,
and slide and remove the PW Sensor Cover together with PW Sensor.
Carriage Unit bottom
Hook
Figure 4-97. Removing the PW Sensor Cover
DISASSEMBLY AND ASSEMBLY
PW Sensor Cover
3.
Disconnect the FFC connected to the PW Sensor.
4.
Remove the PW Sensor from the PW Sensor Cover.
Figure 4-98. Removing the PW Sensor
When reinstalling the PW Sensor, hitch it on the hook of the PW
Sensor Cover.
Refer to Figure 4-97, "Removing the PW Sensor Cover".
Insert the FFC into the PW Sensor securely.
Refer to Figure 4-99, "Removing the PW Sensor".
PW Sensor Cover
Disassembly
PW Sensor Cover
PW Sensor
PW Sensor
Figure 4-99. Removing the PW Sensor