Unit Model Number - Trane R Series Installation, Operation And Maintenance Manual

Air-cooled helical rotary liquid chillers
Table of Contents

Advertisement

Model Number Descriptions

Unit Model Number

Digits 1, 2 — Unit Model
RT =
Rotary chiller
Digit 3 — Unit Type
A
=
Air-cooled
Digit 4 — Development
Sequence
C
=
Development Sequence
Digits 5-7 — Nominal Capacity
120 =
120 Nominal tons
130 =
120 Nominal tons
140 =
120 Nominal tons
155 =
120 Nominal tons
170 =
120 Nominal tons
180 =
120 Nominal tons
200 =
120 Nominal tons
225 =
120 Nominal tons
250 =
120 Nominal tons
275 =
120 Nominal tons
300 =
120 Nominal tons
350 =
120 Nominal tons
375 =
120 Nominal tons
400 =
120 Nominal tons
450 =
120 Nominal tons
500 =
120 Nominal tons
Digit 8— Unit Voltage
A
=
200/60/3
C
=
230/60/3
J
=
380/60/3
D
=
400/50/3
4
=
460/60/3
5
=
575/60/3
Digit 9 — Manufacturing
Location
U
=
Trane Commercial Systems,
Pueblo, CO USA
Digits 10, 11— Design Sequence
XX =
Factory assigned
Digit 12 — Unit Basic
Configuration
N
=
Standard efficiency/performance
configuration
H
=
High efficiency/performance
configuration
A
=
Extra efficiency/performance
configuration
Digit 13 — Agency Listing
N
=
No agency listing
U
=
UL/CUL listing
Digit 14 — Pressure Vessel Code
A
=
ASME pressure vessel code
C
=
Canadian code
D
=
Australian code
L
=
Chinese code
Digit 15 — Evaporator
Application
F
=
Standard (40-60°F) leaving temp
R
=
Low (<40°F) leaving temp
G
=
Remote (40-60°F) leaving temp
RTAC-SVX01J-EN
Digit 16 — Evaporator
Configuration
N
=
2 pass, 0.75" insulation
P
=
3 pass, 0.75" insulation
Q
=
2 pass, 1.25" insulation
R
=
3 pass, 1.25" insulation
Digit 17 — Condenser
Application
N
=
Standard ambient (25-115°F)
H
=
High ambient (25-125°F)
L
=
Low ambient (0-115°F)
W =
Wide ambient (0-125°F)
Digit 18 — Condenser Fin
Material
1
=
Standard aluminum slit fins
2
=
Copper fins
4
=
CompleteCoat epoxy coated fins
Digit 19 — Condenser Fan/Motor
Configuration
T
=
Std fans withTEAO motors
W =
Low noise fans
Digit 20 — Compressor Motor
Starter Type
X
=
Across-the-line starter
Y
=
Wye-delta closed transition
starter
Digit 21 — Incoming Power Line
Connection
1
=
Single point power connection
2
=
Dual point power connection
Digit 22 — Power Line
Connection Type
T
=
Terminal block connection
D
=
Non-fused disconnect switch(es)
C
=
Circuit breaker(s)
Digit 23 — Unit Operator
Interface
D
=
DynaView operator interface
Digit 24 — Remote Operator
Interface
N
=
No remote interface
C
=
Tracer Comm3 interface
B
=
BACnet interface
L
=
LonTalk compatible (LCI-C)
interface
Digit 25 — Control Input
Accessories/Options
N
=
No remote inputs
R
=
External evaporator leaving
water setpoint
C
=
External current limit setpoint
B
=
External leaving water and
current limit setpoint
Digit 26 — Control Output
Accessories/Options
N
=
No output options
A
=
Alarm relay options
C
=
Ice making I/O
D
=
Alarm relay outputs and ice
making I/O
Digit 27 — Electrical Protection
Options
0
=
No short circuit rating
5
=
Default short circuit rating
6
=
High amp short circuit rating
Digit 28 — Flow Switch
T
=
Factory installed flow switch -
water
U
=
Factory installed flow switch -
glycol
Digit 29 — Control Panel
Accessories
N
=
No convenience outlet
A
=
15A 115V convenience outlet
(60Hz)
Digit 30 — Service Valves
1
=
With suction service valves
Digit 31 — Compressor Sound
Attenuation Option
0
=
No compressor sound
attenuation
1
=
Factory installed compressor
sound attenuation
Digit 32 — Appearance Options
N
=
No appearance options
A
=
Architectural louvered panels
C
=
Half louvers
Digit 33 — Installation
Accessories
N
=
No installation accessories
R
=
Neoprene in shear unit isolators
F
=
Flange kit for water connections
G
=
Neoprene isolators and flange kit
Digit 34 — Factory Testing
Options
0
=
Standard functional test
C
=
Customer-witnessed
performance test with report
E
=
Non-witnessed performance test
with report
9