Condenser Nameplate

The condenser ASME nameplate (30 and 60 ton condensers only) is mounted on the
top of the condenser near the water outlet on 60 ton units and on the side of the
condenser near the water outlet on 30 ton units.

Unit Inspection

Carefully inspect chiller while still on shipping conveyance. If unit is damaged or has
broken free from anchorage, require inspection by transportation inspectors. File
damage claims with the carrier and notify a Trane sales representative. The
manufacturer is not responsible for damage occurring during transit. Do not install a
damaged unit without sales office approval.

Inspection Checklist

To protect against loss due to damage incurred in transit, complete the following
checklist upon receipt of the unit:
Inspect individual pieces of the shipment before accepting the unit. Check for
obvious damage to the unit or packing material.
Check the unit for concealed damage before it is stored and as soon as possible
after delivery. Concealed damage must be reported within 15 days.
If concealed damage is discovered, stop unpacking the shipment. Do not remove
damaged material from receiving location. Take photos of the damage, if possible.
The owner must provide reasonable evidence that the damage did not occur after
delivery.
Notify the carrier's terminal of damage immediately by phone and by mail.
Request an immediate joint inspection of the damage by the carrier and the con-
signee.
Notify a Trane sales representative and arrange for repair. Do not repair the unit
until damage is inspected by the carrier's representative.

Loose Parts Inventory

Check all items against shipping list. Water vessel drain plugs, rigging and electrical
diagrams, service literature and optional water temperature sensors are placed inside
the UCP (unit control panel) for shipment before it is shrinkwrapped with waterproof
plastic. When ordered, the optional neoprene isolators are secured in place on the
shipping skid.

Unit Description

Trane Model CGWF/CCAF 20 - 60 ton Scroll Liquid Chillers, utilizing multiple Trane
scroll compressors, are designed for installation indoors. Each unit is completely
assembled hermetic package that is factory-piped, wired, leak-tested, dehydrated,
charged and tested for proper control operation before shipment.
Water inlet and outlet openings are covered before shipment. The units contain an
operating refrigerant charge.The compressors are factory charged with the proper
amount of refrigerant oil.

Unit Model Number

Table 1
Unit Model Number
FCAT
FCODE
M/N digit M/N value Description
MODL
1-4
CGWF
CCAF
Chiller model
CGWF
Water cooled scroll chiller
CCAF
Scroll compressor-chiller (condenserless)