Ping Mode Results; Ping Mode Sample Results - Fluke Series II User Manual

Network assistant
Hide thumbs Also See for Series II:
Table of Contents

Advertisement

OneTouch Series II
Users Manual
To run Traffic Generator in Ping mode, do the following:
1.
Connect the Network Assistant to your network.
2.
Press
(Connectivity Tests) from the top-level
display (for xDSL, press
the Traffic Generator tab and go to step 5).
3.
Press (ITO).
4.
Press the (Traffic Generator) tab.
5.
Press
or
to configure Frames/second to the
desired amount.
6.
Press
or
to configure Frame Length as 60,
64, 128, 256, 512, 768, 1024, 1280, 1518, or 1520
bytes.
The illegal sized frames of 60 and 1520 bytes
most likely will not be responded to by remote
devices.
7.
Select PING as the frame type.
8.
Configure the Target IP Address box by pressing
the box and then entering the address from the
displayed keypad.
7-20
xDSL Test then press
Note
9.
Press
(Start Traffic) to run Traffic Generator.
Traffic is transmitted to the specified Target IP
Address (station or network).
10. Press
( Stop Traffic ) to stop Traffic Generator.
Traffic is transmitted to the specified Target IP Address
(station or network).

Ping Mode Results

Traffic Generator displays Ping mode results as it is
running. You can adjust Frames/second and Frame
Length while Traffic Generator is running to see the
effect of traffic loading on your network or on a station.
Two meters show the Ping mode results. One meter
shows the overall network traffic (in frames per second)
and the other meter shows the rate of Echo Response
packets received from the target device. Figure 7-8
shows Ping mode sample results.