2-2. Pitch time monitor screen No. 2

<Pitch time monitor screen No. 2>
On the ptch tme montor screen No. 2, the total producton volume and the average ptch tme n the
contnuous secton
(Sections A and B in the figure given below) In addition, the display method employed on the pitch time
monitor screen No. 1 is specified.
4
No.
Name
A
Total
The total producton volume n the contnuous secton
producton
screen No. 1 is displayed.
volume display
(Caution) The production volume is approximately 3200 at the maximum due to the restriction by
B
Average pitch
The average ptch tme n the contnuous secton
No. 1 is displayed. It should be noted, however, that pitch time data equal to or longer than 1800
time display
seconds (30 minutes) is judged to be abnormal sewing work and is excluded from calculation.
Graph mode
The mode of graph displayed on the pitch time monitor screen No. 1 is changed over.
1
changeover
Producton volume graph mode :
swtch
Vertcal axs : Producton volume
Horizontal axis : Working time of day
Graph's
The range of the horizontal axis (time unit in one section) of the graph displayed on the pitch time
2
horizontal axis
montor screen No. 1 s set.
range settng
・ Under the production volume graph mode :
swtch
Settng range : 10 m, 15 m, 20 m, 30 m, 1 h, 2 h, 4 h, 8 h, 12 h, 1 d
* "m" represents minute, "h" represents hour and "d" represents day.
・ Under the pitch time graph mode:
Settng range : 3 s, 5 s, 10 s, 15 s, 20 s, 30 s, 1 m
* "s" represents second and "m" represents mnute.
Graph's
The range of the vertical axis of the graph displayed on the pitch time monitor screen No. 1 is set.
3
vertcal range
Settng range: 10, 20, 50, 100, 200, 500, 1000, 2000, 3000, 5000, auto Intal settng : auto
settng swtch
* In the case of "auto," the range is automatically selected to display the production volume on
Producton volume
The producton volume s counted up wth one tem added.
4
count-up swtch
Clear swtch
The pitch time monitor data recorded in the sewing machine memory are cleared.
5
* When this switch is pressed, the clear confirmation popup screen appears. Press
Measurement
Measurement and recordng of sewng machne operaton data are stopped.
6
stop swtch
When measurement is being carried out,
When measurement is in the stop status,
Display
The pitch time monitor screen No. 1 is displayed.
7
changeover swtch
to display the
ptch tme montor
screen No. 1
selected on the pitch time monitor screen No. 1 are measured and displayed.
B
1
2
3
A
1
2
3
the pitch time monitor data capacity.
the vertcal axs as large as possble at all tmes.
to clear the data, or
swtch to cancel clearng.
5
6
7
Descrpton
selected on the ptch tme montor screen
Ptch tme graph mode :
Vertcal axs : Producton volume
Horizontal axis : Pitch time
is displayed.
is displayed.
– 2 –
selected on the ptch tme montor
Intal settng : 30 m
Intal settng : 5 s
swtch