3.14 HEAD OVER-TEMPERATURE PROTECTION
When the head temperature exceeds 70 ºC (158 ºF), the head over-temperature protection will be activated
and the print operation will be paused until the temperature drops down to 55 ºC (131 ºF).
Recheck per
label
* Head temperature will be checked per label.
CG2 Series Operator Manual
Print start
Head temperature check
(Higher than 70 ºC, 158 ºF?)
Yes
Head over-temperature
protection activated
Ongoing print operation
will be paused
ON LINE (POWER)
Green→Red→Off
Recheck head temperature
(Lower than 55 ºC, 131 ºF?)
No
Yes
Print processing
Section 3: Operation and Configuration
No
Print operation will
occur when the head
temperature
becomes lower than
70 ºC (158 ºF).
No print operation will
occur unless the
head temperature
becomes lower than
50 ºC (131 ºF).
Page 3-25