Item
Contents
Option
Cutter
Warning
Buffer near full
Ribbon near end
Head over-heat
protection
AC adapter
protect
CG2 Series Operator Manual
ON LINE
(POWER) LED
Red x twice ->Off
1) Cutter is not connected.
(blinks in long
2) Cut operation was not
interval)
performed successfully.
Green -> Red
1) Free space for receive
buffer is low.
(Lights in turn)
Green-> Red ->Off
1) Remaining amount of
ribbon is little.
(Blinks in turn)
Green -> Red -> Off
1) Goes over the limit of
print head temperature.
Red-> Green -> Off
1) Going over the
maximum print ratio.
Section 4: Troubleshooting
Causes
Corrective Actions
1) Connect the cutter unit.
2) Set and feed the paper
again.
1) Pause the data transmis-
sion on the host side
and wait to have enough
buffer space.
1) Ribbon replacement.
1) Automatically recovers
when print head temper-
ature drops down to
55ºC (131ºF) and below.
1) Automatically recovers
after pausing a certain
period of time.
Page 4-3