Default Setting Mode - SATO CG2 Series Operator's Manual

Direct thermal type 203 dpi/ 305 dpi; thermal transfer type 203 dpi/ 305 dpi
Hide thumbs Also See for CG2 Series:
Table of Contents

Advertisement

Section 3: Operation and Configuration

3.8 DEFAULT SETTING MODE

When default setting mode is selected and executed in Operation Setting mode (refer to Section 3.5
Operation Setting Mode), the printer will reset to the default setting (factory preset) as listed below.
No.
Items to be reset
1
Offset (V, H)
2
Pitch Offset
3
Cut Offset
4
Dispensing Offset
5
Tear-Off Offset
6
Label Size
7
Print Speed
8
Print Darkness
9
Sensor Type
10
Kanji Code
11
Paper End Search
12
Zero Slash
13
Proportional Pitch
14
Initial Feed
15
Auto Feed
16
Operation mode
17
Interface
18
Tear Off Waiting Time
19
Head Check Range
20
RFID Mode
*1. To be connected by Port1024 and Port1025 (2 port connections) or Port 9100 (1 port connection)
Note:
LAN and Wireless LAN setting items cannot be reset to factory default even with the default setting mode.
Page 3-16
Default value
Vertical = 0 dot, Horizontal = 0 dot
0 dot
0 dot
0 dot
0 dot
Pitch 4800 dot x Width 448 dot [203 dpi]
Pitch 4800 dot x Width 672 dot [305 dpi]
75 mm/sec (3 Inches/sec)
5A
Gap
JIS
Roll
Enabled
Enabled
Disabled
Disabled
Continuous
- (No setting)
Tear Off
- (No setting)
Cutter
Mode 1 (Head position)
Dispenser
Mode 1 (Head position)
RS-232C
Baud rate=19200 bps, Data bit=8 bit, Parity=None,
Stop bit=1 bit, Protocol=Protocol for driver
LAN
Protocol for driver (ENQ response mode) *1
USB
- (No initial setting)
1000ms
Normal range (Entire print area)
Disabled