3.3 USER TEST PRINT MODE

This mode produces test labels for diagnostic purposes.
Preparation:
Make sure the media or ribbon (if required) are properly loaded in the printer.
Procedures
1
While pressing
FEED/LINE button, press
POWER button.
2
Release POWER button
and keep holding
FEED/LINE button.
3
Release FEED/LINE
button when ON LINE
(POWER) indicator
changes to solid green
light.
4
Press FEED/LINE button
to start test printing.
Press FEED/LINE button
to pause the test printing.
Press again to resume.
Notes:
If you missed the chance to release the FEED/LINE button in step 3 above, just keep holding the
FEED/LINE button and wait for the next cycle.
If you released the FEED/LINE button at the wrong ON LINE (POWER) indicator, just turn off the power
and restart the procedure.
The printer will continuously print the user test labels until the FEED/LINE button is pressed. The printing is
paused and will resume printing if the FEED/LINE button is press again.
To terminate the User Test Print mode
First, ensure that you have pressed the FEED/LINE button to pause the test printing, then press POWER to
turn off the printer.
CG2 Series Operator Manual
Printer status
Printer start-up
User Test Print Mode.
(The printer will cyclically
advance to next mode as
long as the FEED/LINE
button is held down.)
User Test Print mode
is activated and then
paused.
User Test Print start
and print continuously.
User Test Print paused.
Section 3: Operation and Configuration
ON LINE (POWER) indicator
Solid red light
Solid green light
Solid green light
Blinking green light
Solid green light
Blinking green light
Page 3-5