Switch 4: Unused; Switch 5: Head Check; Switch 6: Vr1 Potentiometer Adjustment Mode - SATO D508 Service Manual

Hide thumbs Also See for D508:
Table of Contents

Advertisement

DIP SWITCH SETTINGS (CONT'D)
Switches 1–3: Font/Graphic loading settings
Enables the loading of fonts and/or graphics into
printer memory for faster retrieval.

Switch 4: Unused

This switch is reserved for future use.

Switch 5: Head Check

Enables or Disables the printer function that checks
the print head automatically.

Switch 6: VR1 Potentiometer Adjustment mode

Selects the function adjusted by VR1. When placed
in the OFF position, VR1 will adjust the media tear-
off / cut (backfeed distance) offset value over a
range of +/- 3.75 mm. When placed in the ON
position, VR1 will adjust the print darkness range.
Page 1-13
DSW1 DSW2 DSW3
Off
On
On
Configuration Switch
ON
OFF
1
2
3
4
DSW4
Mode
Off
DT
On
Reserved
Configuration Switch
ON
OFF
1
2
3
4
DSW5
Mode
Off
Disabled
On
Enabled
Configuration Switch
ON
OFF
1
2
3
4
DSW6
Mode
Off
Media Tear-Off
On
Print Darkness
Configuration Switch
ON
OFF
1
2
3
4
SATO D508/D512 Service Manual
Mode
Load Font
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

D512

Table of Contents