8.2 OPTIONAL ACCESSORIES - DISPENSER (cont'd)
5.
Close the top cover until it clicks into position.
6.
After turning on the label, turn on the power.
The printer is online and the ON LINE (POWER)
indicator lights green.
When the printer is ready, press the FEED/LINE button
to output an empty label and stop at the dispenser. This
procedure is to ensure that the label is loaded correctly.
8.2.2 Stop position Adjustment
Normally, the label is dispensed to the point where 2 or
3mm (0.08" or 0.1") of the label remain on the liner (backing
paper).
If the label is not dispensed at the regular position, use the
Phillips tip of the yellow microdriver attached to the side of the
media holder to adjust the potentiometer VR3 located at the
bottom right of the front panel for the label dispensing stop
position. After adjusting the stop position, dispense two or
three labels to fix the stop position.
Turn left:
The stop position moves in the opposite direction
of the printing direction.
Turn right:
The stop position moves in the same direction as
the printing direction.
Notes:
There may be cases when the dispenser does not function
properly due to the thickness of the labels used.
The Dispenser unit is effective for label pitch 22 to 100 mm
(0.86" to 3.9"). However, the label size limitation may vary
with application conditions.
Labels over 100mm (3.9") may curl at dispenser due to the
nature of the material. There is no remedy for this.
CG2 Series Operator Manual
Section 8: Appendix
Output label
Output
backing
paper
Yellow microdriver
For label dispensing stop position adjustment