Canada only. Power supply cords for use outside of United States and Canada are typically provided
by a third-party distribution center and must meet the following requirements:
Power supply cords must be agency certified for country of use.
●
Power supply cords must contain an appropriate rated and approved wall plug applicable to the
●
country of installation.
The appliance coupler (the connector to the unit and not the wall plug) must have a configuration
●
for mating with an EN60320/IEC320-C14 appliance inlet.
Power supply cords must be less then 15ft (5m) long.
●
The minimum specification for the flexible cable is:
●
No. 18 AWG (.823mm2) for units rated less than 10A, or
●
No. 18 AWG (.823mm2) up to 2m long for units rated 10A or higher, or
●
No. 16 AWG (1.0 mm2) up to 5m long for units rated 10A or higher
●
All cords should be copper stranded, Type SVT or SJT, HAR or equivalent, 3-conductor.
●
Always use an AC power cable appropriate for your country. Check your local electrical codes and
regulatory agencies for power cable requirements. Refer to Data Sheet of PSU at
www.extremenetworks.com
WARNING!
Ensure that the source outlet is properly grounded before plugging the AC supply power cord into a PSU.
Note the following country specific requirements:
Argentina—The supply plug must comply with Argentinean standards.
●
Australia—10 A minimum service receptacle, AS 3112 for 110/220 VAC power supplies.
●
Denmark—The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
●
Japan:
●
10 A service receptacle, JIS 8303 for 110/220 VAC power supplies.
●
The power cord provided with the power supply, controller, or chassis is for use only with that
●
specific product from Extreme Networks; it is not for use with any other product from Extreme
Networks or any other vendors' equipment.
North America—10 A service receptacle, NEMA 5-15 for 110 VAC power supplies and NEMA L6-
●
15P for 208/220 V AC power supplies.
Switzerland—The supply plug must comply with SEV/ASE 1011.
●
United Kingdom—10 A service receptacle, BS 1363 for 110/220 VAC power supplies.
●
International—10 A service receptacle, CEE 7/7 for 110/220 VAC power supplies.
●
France and Peru only:
●
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point
labeled Neutral and connected directly to ground.