P0603536 02
Specify the duration of an Open Switch Interval for a Trunk Cartridge.
Select the minimum duration, in seconds, of an answer signal before a call is
considered to be answered, for an E&M trunk cartridge.
Select the carrier failure standard used by your T1 service provider.
This setting only appears for DTIs.
Interface levels defaults to the ISDN loss plan setting.
Check with your telecommunications service provider to find out the I/F level
of your connection:
• digital network loss treatment (ISDN I/F levels)
• analog network loss treatment (PSTN I/F levels)
Use to select the framing format used by your T1 service provider.
This setting only appears for DTIs.
Use to turn the internal TI channel service on or off.
The channel service unit gathers performance statistics for your T1 lines.
Use to set the gain level of the transmitted signal.
This setting only appears for DTIs that have their internal CSU turned on.
Use to set the distance between the ICS and an external channel service unit.
This setting only appears for DTIs that have their internal CSU set to Off.
Select the standard used by your T1 service provider for encoding signals on
the T1 lines.
Determine the type of clock source.
View the loops on a BRI Card.
View the settings for a particular loop on a BRI Card.
View or change the loop type.
Select the sampling used by an S-loop.
Assign the ISDN DNs that use this loop.
Enter ISDN DNs for each S-loop or LT loop.
Indicate whether or not the DN is assigned to a loop.
Select the main ISDN DN, if any, for the loop.
Enter the SPID supplied by your service provider.
Select the number of B-channels that are associated with the SPID.
Enter the Network DNs that are associated with the SPID.
A Network ISDN DN can be assigned to more than one SPID.
Select the Call type used with the Network DN.
For each ISDN DN, use only one of each of the Voice and Data call type
settings, or a single Both call type setting.
103
Modular ICS 6.1 Programming Record