Table 1 1 Pairevtwait Returned Values
Condition
When the -nowait option is
specified:
When the -nowaits option is
specified:
When the -nowait and/or nowaits
option is not specified:

Error codes

Unrecoverable errors are fixed and not resolved, even after re-executing the command. If the
command failed, the detailed status is logged in the RAID Manager command log ($HORCC_LOG),
even if the user script has no error handling.
Table 12 Specific error codes for pairevtwait
Category
Volume status
Unrecoverable
Timer
Recoverable
Value
Normal termination:
The status is SMPL.
The status is COPY or RCPY.
The status is PAIR.
The status is PSUS.
The status is PSUE.
When monitoring groups, 1/2/3/4/5 = normal termination for all pairs.
Abnormal termination: Other than 0 to 127, see the execution logs for error details.
Normal termination:
The status is SMPL.
The status is COPY or RCPY.
The status is PAIR.
The status is SSUS (S-VOL_PSUS appears as SSUS).
The status is PSUE.
Normal termination: 0. When monitoring groups, 0 = normal termination for all
pairs.
Abnormal termination: Other than 0 to 127, see the execution logs for error details.
Error code
Error message
EX_ENQVOL
Unmatched volume
status within the
group
EX_INCSTG
Inconsistent status in
group
EX_INVVOL
Invalid volume status
EX_EVOLCE
Pair Volume
combination error
EX_EWSUSE
Pair suspended at
WAIT state
EX_EWSTOT
Timeout waiting for
specified status
EX_EWSLTO
Timeout waiting for
specified status on
the local host
Recommended action
Confirm status using the pairdisplay command.
Make sure all volumes in the group have the
same fence level and volume attributes.
Confirm pair status using pairdisplay.
Confirm pair status using pairdisplay -l.
Confirm pair status using pairdisplay, and
change combination of volumes.
Issue pairresync manually to the identified
failed paired volume to try to recover it. If the
trouble persists, call HP Technical Support.
Increase timeout value using -t option.
Confirm that RAID Manager (HORCM) on the
remote host is running.
Value
236
229
222
235
234
233
232
pairevtwait
43