MAINTENANCE
1) Remove the exterior brick panels.
2)
Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
b. Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Door
3) Loosen the 2 screws that hold the left side
heat shield in place.
46

DC SPARKER REPLACEMENT

4) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Heat
Shield
5) Unplug the power source.
6) Loosen the 2 screws that hold the right
side heat shield.
Heat
Shield
Hinge
7) Lift up and pull out the heat shield slightly to
clear the head screws and then hang it on
the top bracket (located directly above the
heat shield).
Heat
Shield
Heat
Shield
8) Remove the battery cover from the DC
Sparker Box.
Bracket
9) Disconnect all the wires and connectors
from the DC sparker.
10) Remove the 2 screws that hold the DC
sparker.
Bracket
11) Replace the DC sparker.
12) Reverse steps to re-install.
Regency
Battery Cover
®
L676 Direct Vent Gas Fireplace