6) Replace the front burner orifi ce with orifi ce
#56. See image below. Use another wrench
to hold onto the elbow behind the orifi ce.
7) Replace the back burner orifi ce with orifi ce
#53. See image below. Use another wrench
to hold onto the elbow behind the orifi ce.
Front Burner
Orifi ce
8) Remove the pilot shield by removing the 2
screws.
Pilot
Shield
9) Remove the clip from the pilot head assembly
using a fl at head screw driver.
Clip
Regency
®
L676 Direct Vent Gas Fireplace
10) Remove the NG pilot orifi ce with the Allen
Key and replace with LP pilot orifi ce.
Rear Burner
Orifi ce
11) Re-install the pilot head and pilot shield.
12) Loosen the 2 screws that hold the right
side heat shield.
Heat
Shield
13) Lift up and pull out the heat shield slightly
to clear the head screws and then hang it
on the top bracket (located directly above
the heat shield).
Heat
Shield
14) Disconnect the 2 grey connectors from
the modulator coil.
15) Remove the right side panel by undoing the
9 screws.
16) Using a Torx T20, remove and discard the
3 pressure regulator mounting screws.
Remove the modulator coil and the
gasket.