INSTALLATION

CONVERSION KIT #521-969 FROM NG TO LP

LP Conversion instructions for BEFORE UNIT INSTALLATION.
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!
LP Conversion Kit Contains:
Qty. Part #
Description
1
910-462
LP Conversion Coil
1
904-573
Cable Tie
1
910-037
LP Pilot Orifi ce
1
904-345
Orifi ce #53 (back)
1
904-241
Orifi ce #56 (front)
1
904-529
Allen Key
1
918-590
LP Conversion Decal
1
908-528
Red Propane Label
1
918-596
Instruction Sheet
1) Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
28
b. Swing the door out from the top and
release the hinges on the left and right
side of the door by lifting them up.
Door
c. Place the door on a soft surface to prevent
scratching.
2) Remove the grate by undoing the 2 screws
on the right and left side.
Grate
3) Remove the front burner by removing the
screw.
Front Burner
Hinge
Front Burner Removed
4) Remove the back burner by removing the
screw.
5) Remove the rear log stand by removing
the 4 screws.
Rear Log Stand
Regency
®
L676 Direct Vent Gas Fireplace
Back Burner