Dc Sparker Replacement; Power Module Replacement - Regency P40-LP Owners & Installation Manual

Regency gas fireplace owners and installation manual
Table of Contents

Advertisement

DC SPARKER
REPLACEMENT
1) Unplug the power source.
2) Remove the manual control panel by
removing the 2 screws.
Manual Control Panel
3) Remove the DC Sparker by removing the 2
screws that secure the DC Sparker to the
fi rebox and lift out.
DC Sparker
Regency
®
P40-1 Direct Vent Gas Fireplace
4) Remove the cover on the DC Sparker and
unplug the red (+) and black (-) wires.
Note: Ensure that the ring tabs on the wire
fi t behind the metal posts when re-
installing.
Ring Tabs
5) Unplug pilot knob wires (Wa and Wb) and
ignitor wire (Vu).
Wa & Wb Wires
6) Replace the DC Sparker and reverse steps
to re-install.
MAINTENANCE
POWER MODULE
REPLACEMENT
1) Unplug the power source.
2) Remove the Power Module by lifting it up off
of the velcro and pull out.
3) Remove the Power Module cover by
removing the 2 screws, one on each side
of the box.
Vu Wires
4) Unplug all wires connected to the Power
Module (J1, J2 & J3 on the power module
circuit board).
J1
5) Pull Power Module off of pins and replace.
6) Reverse steps to re-install.
Power Module
J3
J2
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P40-ngP40

Table of Contents