Control Module Replacement - Regency LIBERTY L676-NG Owners & Installation Manual

Table of Contents

Advertisement

1) Remove the exterior brick panels.
2)
Remove the glass door.
a. Release the 2 door latches on the left
and right side at the top of the fi rebox.
Latch Location
Latch
b. Swing the door out from the top and release
the hinges on the left and right side of the
door by lifting them up.
Door
Regency
®
L676 Direct Vent Gas Fireplace

CONTROL MODULE REPLACEMENT

3) Loosen the 2 screws that hold the left side
heat shield in place.
4) Lift up and pull out the heat shield slightly
to clear the screwheads and then hang it
on the top bracket (located directly above
the heat shield).
Heat
Hinge
Shield
5) Unplug the power source.
6) Cut the cable tie that is holds the wires
connected to the control module.
Control Module
MAINTENANCE
7) Disconnect the 3 connectors from the
control module.
Heat
Shield
8) Pull out the control module.
NOTE: The control module is held in place
with velcro.
Bracket
9) Replace the control module
10) Reverse steps to re-install.