MAINTENANCE
CONTROL MODULE
REPLACEMENT
1) Unplug the power source.
2) Remove the Power Module by lifting it up
off of the velcro and pull out.
Power Module
3) Remove the Control Module by lifting it up
off of the velcro and pull out.
Control Module
48
4) Remove the Heat Shield from the Control
Module by removing the 2 screws.
Heat Shield
5) Unplug all wire harnesses and manual
control box cable plugged into the Control
module.
6) Replace the Control Module and reverse
steps to re-install.
BACKUP BATTERY
REPLACEMENT
(within Power Module)
NOTE: The 9V battery operates the
rear burner under power outage
conditions.
The AA battery operates the DC
Sparker for lighting the pilot.
1) Unplug the power source.
2) Remove the Power Module by lifting it up
off of the velcro and pull out.
Power Module
3) Remove the Power Module cover by
removing the 2 screws, one on each side
of the box.
4) Replace the 9V and AA battery and reverse
steps to re-install.